Tripp Lite series SmartOnline 1500VA 1350W 208/230V Double-Conversion UPS - 8 Outlets, Extended Run, Network Card Option, LCD, USB, DB9, 2U Rack/Tower
Product Name |
Eaton Tripp Lite series SmartOnline UPS
|
Catalog Number |
SUINT1500LCD2U
|
UPC |
037332248077
|
Product Length/Depth |
17.72 in
|
Product Height |
3.41 in
|
Product Width |
17.33 in
|
Product Weight |
41.45 lb
|
Compliances |
RoHS
ENERGY STAR certified CE Marked FCC Compliant REACH |
Certifications |
UL 1778
CSA certified CSA 22.2 cTUVus NOM |
Global Catalog |
SUINT1500LCD2U
|
Battery replacement |
EBP-1613 *Note: EBP-1613 is the replacement battery for the SUINT1500LCD2U 2023 UPS design update featured on this page. For the replacement battery in the previous design of SUINT1500LCD2U, please see part number RBC36S
|
Battery type |
Valve Regulated Lead Acid (VRLA)
|
Extended battery capability |
Add up to 4 extended battery modules (EBM). Part number BP48RT
|
Runtime at full load |
5.8 min. (1350W)
|
Runtime at half load |
16 min
|
Output Voltage Regulation (Line Mode) |
+/- 1%
|
Output Voltage Regulation(Battery Mode) |
+/- 1%
|
Receptacle |
(8) C13
|
Topology |
Online/Double-conversion
|
Wattage |
1350 W
|
Output waveform |
True sine wave
|
Output power factor |
0.9
|
Voltage |
208 V
|
Output voltage range |
±1% steady-state
|
Output nominal voltage |
208V default (200/208/220/230/240/250V)
|
Output frequency |
50/60 Hz
|
Number of Outputs C13 |
8
|
Current Crest Ratio |
3:1
|
Input connection |
C14
|
Input cord length |
6 ft
|
Input nominal voltage |
200 VAC/208 VAC/220 VAC/230 VAC/240 VAC
|
Input power factor |
.99
|
AC suppression joule rating |
296
|
Communication |
|
Expansion slots |
|
Includes network card |
No
|
User interface |
LCD display
|
Altitude |
0-1500m (0° to 40°C), 1500-3000m (0° to 35°C)
|
BTU Rating |
Online: 494, Battery: 731
|
Noise level |
<40 dB at 1 meter
|
Relative humidity |
0-96% non-condensing
|
Temperature range |
0° to 40°C (32° to 104°F)
|
Storage Temperature |
With battery: 32° to 104°F (0° to 40°C); without battery: -13° to 131°F (-25° to 55°C)
|
Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
Form factor |
Rack/tower
|
Rack size |
2U
|
Rack mounting kit |
Yes
|
Switch configuration |
RPO / ROO
|
Phase (input) |
Single-phase
|
Surge protection |
Yes
|
Internal bypass |
Yes
|
Package contents |
|
EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
Green Energy-Saving Features |
High efficiency economy mode operation
Individually controllable load banks |
Standard factory warranty |
2-year limited
|
Extended service plans |
|